Driven steel W-beam solar piles (W6 & W8 series)

Section properties, steel grades, galvanizing, embedment and logistics for the workhorse utility solar foundation.

AISC wide-flange section properties

Nominal properties from the AISC Shapes Database for the W-shapes used as solar piles. Steel is ASTM A572 Grade 50 or A992 (50 ksi minimum yield).

Sectionlb/ftDepth d (in)Flange bf (in)Web tw (in)Flange tf (in)Ix (in⁴)Sx (in³)Typical solar use
W6x8.58.55.833.940.1700.19514.95.10Light tracker interior posts, benign soils, low wind
W6x99.05.903.940.1700.21516.45.56Utility workhorse interior / line post
W6x1212.06.034.000.2300.28022.17.31Exterior rows, slew/motor drives, moderate wind or corrosion
W6x1515.05.995.990.2300.26029.19.72High wind, hurricane and snow zones; motor posts
W8x1010.07.893.940.1700.20530.87.81Strong-axis stiffness at moderate weight
Source: AISC Shapes Database. A W6x7 is rolled by some mills for solar but is not in the standard AISC manual tables; confirm properties with the mill.
8.5–15lb/ft across the W6 range
0.170–0.230"web thickness
3.9–4.7 milsASTM A123 minimum average zinc
44,000 lbper flatbed load

Steel and galvanizing

  • Grade: ASTM A572 Grade 50 is standard. Grade 65 lets a lighter section carry the same moment where the racking OEM allows it. A992 is accepted interchangeably for W-shapes.
  • Fabrication: cut to length, then CNC punched or slotted for the tracker bearing housing or fixed-tilt bracket. Hole patterns follow the racking OEM's drawing, so confirm the revision before the mill cut.
  • Galvanizing: hot-dip after fabrication to ASTM A123. Reactive (Si/P) steel picks up a heavier, darker coat of 5.5–7.5+ mils, which adds corrosion life. Specify it when the soil report is aggressive.

Embedment and length

RackingTypical embedmentTotal lengthPiles per MWdc
1P / 2P single-axis tracker7.0–10.0 ft10–15 ft (3–5 ft reveal)250–350 (range 220–400)
Fixed-tilt ground mount5.0–8.0 ft8–13 ft300–450+

Embedment is set by uplift and lateral demand from ASCE 7 wind and snow loads, checked against load tests. A pre-construction ASTM D3689/D3966 test program often takes 1.5–3 ft off every pile.

Shipping and staging

A 25 MWdc tracker block on 12 ft W6x9 piles is roughly 7,400 piles and 400 tons of steel, about 18 to 20 flatbed loads. Bundles are banded by length and punch pattern, tagged by heat number for the MTR package, and staged along the access roads so pile carts can feed the rigs. Galvanized steel should be stored off the ground on dunnage to prevent wet-storage stain.

Ground-mounted solar array on driven steel posts
Driven posts on a fixed-tilt array in arid soil.

Run your own take-off in the pile estimator, or check year-30 web thickness in the corrosion checker.

Send the pile schedule. Get a foundation bid.

MWdc, racking, geotech status and mobilization window are enough to start. Steel supply, driving crews, ground screws, pre-drilling and load testing priced as one package or line by line.